NIST 2930 VIS Photometric Neutral Density Kit (0.1%T, 0.3%T, 90%T) (400-700nm)
NIST 2930 VIS Photometric Neutral Density Kit (0.1%T, 0.3%T, 90%T) (400-700nm)
Firefly's equivalent of the NIST SRM 2930 calibration reference kit for testing photometric accuracy in the VIS range (400-700nm). This kit comes with Firefly's Lifetime Warranty and never requires recalibration.
This includes the following filters:
Capabilities:
Photometric accuracy verification in the VIS range (400-700nm)
Product Specs:
Wavelength range: 400-700nm. Standard validation points included on the certificate of calibration are 440, 465, 546.1, 590, 635nm.
Tolerances: HF-0.04 (+/- 0.0020 au); HF-2.5 (+/- 0.0090au); HF-3 (+/- 0.0181au)
External dimensions of individual filters: 12.5 x 12.5 x 45.0 mm
Benefits of using Firefly's Solid-State Calibration Standards:
Highly accurate and consistent spectrophotometer calibration every time.
Never has to be replaced.
Never has to be recalibrated if used properly.
Scratch-resistant coating protects optical surfaces
Can be used in any spectrophotometer (with standard 12.5 x 12.5 x 45.0 mm holder)
Surpasses NIST-2930 requirements and tolerances
NIST-compliant
Sample NIST-2930 Certificate of Calibration
Customers Who Bought This Also Bought:
Firefly's HF neutral density solid-state filter series tests photometric accuracy in the VIS range (400-700nm).
The WAV-1 UV-VIS allows calibration of wavelength accuracy in the ultra-violet (UV) and visible (VIS) range. FireflySci offers the only holmium glass reference standard in the world that has the highly demanded wavelength peak of 241.5nm for verifications relating to DNA measurements and other applications.
Firefly's FUV neutral density solid-state filter series tests photometric accuracy in the UV and VIS range from 200-700nm. Our solid-state nano-deposition technology produces unparalleled stability and keeps the filter in spec for years.
WAV-7 Didymium glass combined wavelength accuracy (329-875nm) and photometric accuracy (270-340nm) filter.



![firefly_logo_FINAL [Black].jpg](https://images.squarespace-cdn.com/content/v1/5411d5c0e4b02e1c8b27565a/1434491508803-XB4OF7YDY46Z72L5U5AP/firefly_logo_FINAL+%5BBlack%5D.jpg)


Become an educated spectrophotometer calibration expert with this one video.