Superband Series: Full UV/VIS/NIR Photometric Accuracy Calibration Standards (200-3000nm) (Optical Densities: 0.04 - 4.0au)

SPB-0.png
SPB-0.png

Superband Series: Full UV/VIS/NIR Photometric Accuracy Calibration Standards (200-3000nm) (Optical Densities: 0.04 - 4.0au)

$3,736.00

It's a bird, it's a plane, it's SUPERBAND! The mother of all calibration standards has arrived!

FireflySci is proud to announce the only calibration standard in existence that can verify photometric accuracy over a wavelength range of 200-3000nm.

Absorbance (Transmission) Value:
Quantity:
Add To Cart

Sample Superband Certificate of Calibration

Sample Superband Certificate of Calibration

Capabilities:

  • Photometric accuracy in the UV, VIS and NIR range (200-3000nm) at 10 certified wavelengths including: 250, 360, 465, 546.1, 635, 1100, 1700, 2210, 2500, 2850nm (in some cases, the wavelength point of 2850nm will need to be 2800, 2900 or 2950nm due to random material variance).

Product specs:

  • Optical densities: 0.04au, 0.2au, 0.3au, 0.5au, 0.7au, 1.0au, 1.5au, 2.0au, 2.5au, 3.0au

  • Uncertainties: SPB-0.04 (+/- 0.0019au), SPB-0.2 (+/- 0.0022au), SPB-0.3 (+/- 0.0020au), SPB-0.5 (+/- 0.0022au), SPB-0.7 (+/- 0.0023au), SPB-1.0 (+/- 0.0042au), SPB-1.5 (+/- 0.0054au), SPB-2.0 (+/- 0.0055au), SPB-2.5 (+/- 0.0090au), SPB-3.0 (+/- 0.0181au), SPB-4.0 (+/- 0.0234au).

  • Wavelength range: 200-3000nm. FireflySci can provide certified calibration points anywhere in this range. Customers are able to choose points.

  • External Dimensions: 12.5 x 12.5 x 45 mm

Benefits of using Superband Photometric Accuracy Filters:

  • Highly accurate and consistent spectrophotometer calibration every time

  • Never has to be replaced

  • Never has to be recalibrated if used properly

  • Scratch-resistant coating protects optical surfaces

  • Can be used in any spectrophotometer (with standard 12.5 x 12.5 x 45mm holder)

  • Surpasses NIST-2031a requirements

  • Full NIST traceability and compliance

SPB-1.0 Absorbance Scan

The SPB-Series filter maintains remarkable stability throughout the UV, VIS and NIR range

Customers Who Bought This Also Bought:

WAV-8 NIR Wavelength Accuracy Standard (700-3000nm)
$2,490.00

FireflySci's solution for wavelength calibration through the NIR range (700-3000nm).

FUV Dual Series: UV/VIS Photometric Accuracy & Stray Light Calibration Standards (200-700nm) (Optical Densities 0.2-4.0au)
$2,488.00

Firefly's FUV Dual Series filters allow you to verify photometric accuracy and stray light in the range of 200-700nm. 

Ultimate UV/VIS/NIR Photometric, Wavelength & Stray Light Calibration Kit
$11,150.00

Broad range solid-state standard kit for checking photometric accuracy, wavelength accuracy and stray light in the UV, VIS AND NIR range.

For use with research-grade UV/VIS/NIR spectrophotometers.